Overview#
MaxRingDelta in
EDirectory Lists the amount of
data which might not be successfully synchronized to all the
Edirectory Replicas and is viewable in
imonitor and in
EDirectory 9.0.0.0 (40002.79) and later in the
cn=Partition, cn=Agent, cn=monitor
MaxRingDelta shows the amount of data that will be lost when that server dies (all data back to 1970, or the beginning of computer time).
For example, if a user has changed his or her login script within the past 30 minutes, and the MaxRingDelta has a 45-minute allocation, the user's login might not be successfully synchronized, and he or she might get the previous login script when he or she attempts to log in.
However, if the user changed the login script more than 45 minutes ago, he or she should get the new login script consistently from all replicas.
There might be more information for this subject on one of the following: